Produkte:
GLINDEMANN® PTFE Dichtringe für
Kegelschliffe
(Normschliffe, Laborglas-Apparaturen)
Hersteller und Adresse:
Dr. Dietmar Glindemann
Goettinger Bogen 15
D-06126 Halle, Germany,
ph +49-(0)345-6879948, fx +49-(0)345-6871333. e-mail
dglinde@aol.com (Dietmar Glindemann)
Internet : www.glindemann.net
Links in dieser Seite:
Händler und ihre Katalog-Nummern
Lieferumfang und Preise
Anwendungen
Gebrauchsanweisung
Test-Berichte (Referenzen)
Händler von GLINDEMANN®
Dichtringen
und ihre Katalognummern.:
List
of distributors of GLINDEMANN® sealing rings
and their catalogue numbers (to find distributor addresses in single countries, see next table) |
|||||||||||
Joint maximum diameter / mm | 7 | 10 | 12 | 14 | 19 | 24 | 29 | 34 | 45 | 70 | Distribution in |
Glindemann No | K7 | K10 | K12 | K14 | K19 | K24 | K29 | K34 | K45 | K70 | |
Number of Sealing rings / unit (pck) | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |
Distribution worldwide by
SIGMA-ALDRICH
(click link to find addresses for over 200 countries worldwide). Prizes up to 50% higher, but ordering is convenient in any country. Search for "glindemann" or enter Sigma-Aldrich catalogue number below |
|||||||||||
Sigma-Aldrich Labware Catalogue) | Z50,198-0
(Z501980) |
Z50,208-1 (Z502081) |
Z50,220-0 (Z502200) |
Z50,231-6 (Z502316) |
Z50,241-3 (Z502413 ) |
Z50,252-9 (Z502529) |
Worldwide 200 countries | ||||
Distribution
in USA, Canada, Mexico by
Sigma-Aldrich. Starting November 2009, customers of VWR, Fisher Scientific, Thomas Scientific use Aldrich-catalogue numers. Please contact Dr. Glindemann at dglinde@aol.com if you currently experience ordering problems. |
|||||||||||
Distribution in Australia and Europe | |||||||||||
LABGLASS | GSR7 | GSR10 | GSR12 | GSR14 | GSR19 | GSR24 | GSR29 | GSR34 | GSR45 | GSR704 | Australia, Oceania |
AJ Cope & Son Ltd, on-line shop Thelabwarehouse.com |
QZZ27/14 | QZZ27/19 | QZZ27/24 | QZZ27/29 | QZZ27/34 | QZZ27/45 | UK, Ireland![]() |
||||
Carl Roth GmbH,
|
T221.1 | E699.1 | E700.1 | E701.1 | E702.1 | T222.1 | Europe![]() |
||||
Glass Solutions Ltd | K14 | K19 | K24 | K29 | K45 | UK, Ireland![]() |
|||||
Fisher-Scientific in Germany |
10125930 (3391345) |
10268410 (3391346) |
10228460 (3391347) |
10636521 (3391348) |
10782131 (3391349) |
10646521 (3391350) |
10390001 (3391351) |
10257790 (3391352) |
10686901 (3391353) |
Germany, Austria, Switz. | |
VWR International in Germany | 2016251 | 2016252 | 2016253 | 2016256 | 2016258 | 2016260 | 2016262 | 2016263 | 2016264 | 2016266 | Germany, Austria, Switz. |
Lab Logistics (Quadrolab, LHU), link to 12 European countries | 9.011 663 | 9.011 664 |
9.011 665 | 9.011 666 | 9.011 667 |
|
|
Europe | |||
LR. Vetter Laborbedarf e.K. | DKA-7 | DKA-10 | DKA-12 | DKA-14 | DKA-19 | DKA-24 | DKA-29 | DKA-34 | DKA-45 | DKA-70 | Germany |
AMSI | 6.300.007 | 6.300.010 | 6.300.012 | 06.300.014 | 06.300.019 | 06.300.024 | 06.300.029 | 6.300.0344 | 6.300.045 | 6.300.070 | Switzerland |
Addresses of distributors, in countries, worldwide, (to find catalogue numbers, see table above) |
||||
Catalogues of company (click on links to see addresses) | Address |
Phone, Fax, e-mail |
Catalogue
numbers (see table above) |
Country of Distribution |
Sigma-Aldrich (Sigma-Aldrich
Labware Catalogue) Prizes about 50% higher, but ordering is convenient. Click link to find 200 countries. Search for "glindemann" |
ALDRICH | Worldwide, 200 countries, ![]() |
||
Lab Logistics (Quadrolab) in UK,
Irleand |
The Oval, Hackney Road, London E2 9DU, UK | Ph: (0044) 0207 729 2405, Fx: (0044) 0207 729 2657, cjc@ajcope.co.uk | Lab Logistics (Quadrolab) | UK, Ireland![]() |
AJ Cope & Son Ltd,
on-line shop Thelabwarehouse.com |
The Oval, Hackney Road, London
E2 9DU, UK |
Ph: (0044) 0207 729 2405, Fx:
(0044) 0207 729 2657, cjc@ajcope.co.uk http://www.thelabwarehouse.com/home.html |
Lab Logistics (Quadrolab) | UK, Ireland![]() |
Carl Roth in UK,
Ireland ROTEC SCIENTIFIC LTD. |
10, Bridgeturn Avenue, Old Wolverton, GB-Milton Keynes MK 12 5QL, UK | Ph: 01908 22 33 99, Fx: 01908 22 30 00, Sales@techmate.co.uk |
Carl Roth (ROTH) | UK, Ireland![]() |
Glass Solutions Ltd. |
Unit 2 149b Histon
Road, Cambridge CB4 3JD |
Ph: (0044) 01223 301929, Fx: (0044) 01223 301623, enquiries@glass-solutions.co.uk | Glass Solutions Ltd. | UK, Ireland![]() |
Lab Logistics (Quadrolab) in Austria Bartelt , Wagner & Munz Austria |
click link |
click link | Lab Logistics (Quadrolab) | Austria |
Carl
Roth in Austria LACTAN GesmbH & Co. KG |
Zinzendorfgasse 10-12, A-8011 Graz | Ph: 0316/32 36 92-0 Fx: 0316/38 21 60 Lactan.Labor@aon.at |
Carl Roth (ROTH) | Austria |
LABGLASS |
24 Windorah St, Stafford, Brisbane, Queensland, 4053, Australia |
Ph:
++61(0)7-3356 8199 |
LABGLASS | Australia, New Zealand, Oceania |
Lab Logistics (Quadrolab) in Belgium Devos-Francois S.A. |
480, rue de Châtelet B- 6010 Charleroi, Belgium |
Ph: ++32(0) 71 440870 Fx: ++32(0)71 440890 e-Mail: mail@d-f.be | Lab Logistics (Quadrolab) | Belgium |
Carl Roth in Czechia - Ceska P-LAB A.S. |
Ricanska 10, CZ-10100 Praha 10 |
Ph: 02/171-380 00, -322 02, Fx: 02/171-311 76, info@p-lab.com | Carl Roth (ROTH) | Czechia - Ceska |
Lab Logistics (Quadrolab) in Denmark Bie & Berntsen , Buch & Holm |
click link |
click link | Lab Logistics (Quadrolab) | Denmark |
Lab Logistics (Quadrolab) in Spain Serviquimia s.a. |
Pere IV 29-35, 5° 1°, E-08018 Barcelona, Spain | Ph: 0034 (0)93 3003493, Fx: 0034 (0)93 3003493, serviquimia@serviquimia.com | Lab Logistics (Quadrolab) |
Spain - Espagna - Portugal |
Carl Roth in
Spain Carl Roth S.L. |
La Jota, 86, E- 08016 Barcelona | Ph: 93-3 52 60 61, Fx: 93-3 49 80 23, carl.roth@retemail.es | Carl Roth (ROTH) |
Spain - Espagna Portugal |
Carl Roth in France Roth-Sochiel S.A.R.L |
3, rue de la Chapelle/B.P. 11, F-67630 Lauterbourg, France |
Ph: 03 88 94 82 42 Fx: 03 88 54 63 93, sochiel@carlroth.de |
Carl Roth (ROTH) | France |
Lab Logistics in
France Sodipro S.A. |
42, rue Ambroise Croizat, BP 307, F-38434 Echirolles Cedex, France |
Ph: 0033 (0)4 7623 3927, Fx 0033 (0)4 7623 2412, sodipro.38@wanadoo.fr | Lab Logistics (Quadrolab) | France |
Fisher Scientific Germany | Im Heiligen Feld 17 58239 Schwerte |
Ph++49 (0)2304
/ 932-800 |
Fisher Scientific Germany | Germany, Austria, Switzerland |
VWR in Germany | John Deere Str. 5, |
Ph++49
(0)7251/717-0 |
Merck Eurolab (VWR) | Germany, Austria, Switzerland |
Lab Logistics Germany | Postfach 1416 |
Ph++49(0)2225-948690,
|
Lab Logistics (Quadrolab) | Germany |
LR. Vetter Laborbedarf e.K. | Herrenberger Str. 5, D-72119 Ammerbuch, Germany | Ph++49(0)7073/6936, Fx++49(0)7073/2740 | Vetter | Germany |
Carl Roth GmbH, Germany | Schoemperlenstr. 3, D-76185 Karlsruhe, Germany |
Ph++49
(0)721/5606-0, |
Carl Roth (ROTH) | Germany |
Lab Logistics in Italy EXACTA + OPTECH labcenter s.p.a. | click link | click link | Lab Logistics (Quadrolab) | Italy |
Lab Logistics in the Netherlands Boom B.V. |
P.O. Box 37 NL-7940 AA Meppel Rabroekenweg 20 NL- 7942 JE Meppel | Ph: ++31(0)522 268700 Fx: ++31 (0)522 260779 boombv@boomlab.nl | Lab Logistics (Quadrolab) | Netherlands |
LABGLASS |
24 Windorah St, Stafford, Brisbane, Queensland, 4053, Australia |
Ph:
++61(0)7-3356 8199 |
LABGLASS | New Zealand, Oceania |
Lab Logistics in Norway INSTRUMENT-TEKNIKK A/S BIOTEST (Member of the Bie & Berntsen-Group0 | Grini Naeringspark 1/PB 14 N-1332 Oesteraas (Oslo) | Ph: ++47 (0)671 49303 Fx: ++47 (0)671
49302 firmapost@instrument-teknikk.no |
Lab Logistics (Quadrolab) | Norway |
Carl Roth in Poland Linegal Chemicals Sp.z o.o. |
ul. Kasprzaka 44/52, PL-01-224 Warszawa | Ph: 022/632-32 21 w.-33 74,-31
92,-32 91, Fx: 022/631-72 81 |
Carl Roth (ROTH) | Poland - Polska |
Lab Logistics in Sweden Bie & Berntsen, Buch & Holm |
click link | click link | Lab Logistics (Quadrolab) | Sweden |
AMSI | Geismet 11, CH-4317 Wegenstetten AG, Switzerland |
Ph ++41-(0)61-8739093, Fx ++41-(0)61-8739094 | AMSI | Switzerland |
KIMBLE-KONTES | 1022 Spruce Street, Vineland, NJ 08360 | Ph ++1-609-692-8500, Fx ++1-609-692-3242 | Kimble-Kontes | USA/Canada/Mexico |
VWR USA | 1310 Goshen Parkway West Chester, PA 19380, USA |
Ph 1-800-932-5000, Phone: (610)
431-1700 Fax: (610)431-9174 |
VWR USA | USA/Canada/Mexico |
Fisher-Scientific USA | Fisher Scientific Worldwide, Export Division, 50 Fadem Road, Springfield, NJ 07081-3193, USA |
Phone:
1-973-467-6511, |
Fisher-Scientific USA | USA/Canada/Mexico |
ALDRICH
(since September 2002) Prizes up to 50% higher, but ordering is convenient. Click link to find 200 countries |
ALDRICH | Worldwide, 200 countries |
zurück zum Anfang
Lieferumfang: Für alle Schliff-Grössen.
1 Verpackungseinheit (VE) = 50
Dichtringe auf einem Rohr oder Kegel, passend zum Durchmesser des Schliff-Kerns, in
beschriftetem Beutel, inklusive Information zur Handhabung in verschiedenen Sprachen.
information in several languages:
50 Dichtringe auf einem Speicherrohr 50
Dichtringe auf einem Speicher-Kegel
Farbfoto:
Speicher-Rohr mit 50 Dichtringen,
passend for Schliff NS 29
Verbraucher-Preise in Europa: 1 Verpackungseinheit (50 Ringe) ca. 25 EURO (fragen Sie
Ihren Händler).
Lieferung: 50 Dichtringe auf einem Rohr oder Kegel, passend zum Kern des Schliffs. |
Der Dichtring sieht auf guten Schliffen "dicht" wie Fett aus. |
Links: Dichtring vor dem Anpressen der 2 Schliff-Teile
Mitte: Dichtring nach dem Anpressen - transparent wie Fett. Unter Druck fliesst das PTFE wie Fett in die Unebenheiten der Oberfläche des Schliffs.
Rechts: Vergleich mit einem gefettetten Schliff, ebenfalls transparent. Aber Fett ist nicht Lösungsmittel-resistent und nicht sauber.
Test-Bericht über
GLINDEMANN-PTFE-Dichtringe für Kegelschliffe
von
Dr. Andreas Bolte
Arbeitsgruppe von Prof. Dr. Borislav Bogdanivic, Max-Planck-Institute für Kohleforschung,
Germany
Kaiser-Wilhelm-Platz 1, D-45470 Mühlheim a. d. Ruhr, Germany
Sehr geehrter Herr Dr. Glindemann:
Unsere anorganische und organometallische Laborforschung benötigt of absolut saubere und
dichte Schliffe an Glasapparaturen. Ihre PTFE-Dichtringe wurden als sehr brauchbar
befunden für:
Langzeit-Abdichtung von Hochvakuum-Apparaturen,
Langzeit-Abdichtung von inerten Apparaturen bis 200oC,
Abdichtung von Apparaturen und Behältern für die Synthese und Lagerung von gefährlichen
und pyrophoren (entflammbaren), Sauerstoff-empfindlichen und Feuchtigkeits-empfindlichen
Chemicalien,
Abdichtung von Apparaturen, bei denen die Kontamination von Reaktions-Mischungen durch
Schliff-Fett zu vermeiden ist.
Unsere Gruppe ist dazu übergegangen, Glindemann-Dichtringe an Stelle von Fett oder
PTFE-Manschetten zu benutzen, infolge ihrer überraschenden Abdichtungs-Eigenschaften und
der Vorteile des Arbeitens mit Fett-freien Schliffen.
(gekürzt)
Wir betrachten Ihre PTFE-Dichtringe als die derzeit beste Möglichkeit, mit fettfreien
und dichten Schliffen zu arbeiten.
(Unterzeichnet von Andreas Bolte)